    Pressure model of a four-way spool valve for simulating electrohydraulic control systems

    Get PDF
    An equation that relates the pressure flow characteristics of hydraulic spool valves was developed. The dependent variable is valve output pressure, and the independent variables are spool position and flow. This causal form of equation is preferred in applications that simulate the effects of hydraulic line dynamics. Results from this equation are compared with those from the conventional valve equation, whose dependent variable is flow. A computer program of the valve equations includes spool stops, leakage spool clearances, and dead-zone characteristics of overlap spools

    Control system for an artificial heart

    Get PDF
    Inexpensive industrial pneumatic components are combined to produce control system to drive sac-type heart-assistance blood pump with controlled pulsatile pressure that makes pump rate of flow sensitive to venous /atrial/ pressure, while stroke is centered about set operating point and pump is synchronized with natural heart

    Electronic circuit detects left ventricular ejection events in cardiovascular system

    Get PDF
    Electronic circuit processes arterial blood pressure waveform to produce discrete signals that coincide with beginning and end of left ventricular ejection. Output signals provide timing signals for computers that monitor cardiovascular systems. Circuit operates reliably for heart rates between 50 and 200 beats per minute

    Cardiac R-wave detector

    Get PDF
    Cardiac R wave detector obtains the systolic contraction signal of the human heart and uses it as a reference signal for the heart-assist pump cycle. It processes the electrocardiac signal /QRS wave complex/ of the natural heart in a sequence of operations which essentially elimates all components from the input signal except the R wave

    Circuit for detecting initial systole and dicrotic notch

    Get PDF
    Circuitry is disclosed for processing an arterial pressure waveform to produce during any one cycle a pulse corresponding to the initial systole and a pulse corresponding to the dicrotic notch. In a first channel, an electrical analog of the arterial pressure waveform is filtered and then compared to the original waveform to produce an initial systole signal. In a second channel, the analog is differentiated, filtered, and fed through a gate controlled by pulses from the first channel to produce an electrical pulse corresponding to the dicrotic notch

    Sinusoidal-pressure generator for testing dynamic pressure probes

    Get PDF
    Generator can produce sinusoidal pressures at frequencies from 300 to 5000 Hz and peak-to-peak amplitudes up to 5.6 lbs/sq in. Amplitude and phase-angle measurements made at various frequencies are compared with measurements from a piezoelectric transducer mounted flush with the resonant tube wall